hot Products

Newest Lipo Laser Slimming Pad 25 Diodes/36 Diodes 100mw, 650nm

Newest Lipo Laser Slimming Pad 25 Diodes/36 Diodes 100mw, 650nm

Lipo Laser Slimming Pad 25 Diodes/36 Diodes

  • Product Details

Wavelength 650nm
Energy output 25 x 100mW , 36 x 100mw
Voltage AC110V-240V/50Hz-60Hz
Diode laser type Mitsubishi ML101J27
Safety On Board Diagnostics
Classification Electrical Class 1, Type B applied part
Cooling requirements Air cooling
Mode of operation Continuous
Diodes standard 25 diodes or 36 diodes
Environmental requirements: 0°C to 40°C Non-condensing Humidity Below 75%RH
Package Size 25cm*17cm*15cm
N.W & G.W: 1.0kgs / 1.2kgs
Accessory list Lipo laser pad * 1pc
Power line * 1pc
Elastic bands *3pcs

How It Works?

3D Lipo Slimming Pads emits low levels of laser energy, which creates a chemical signal in the fat cells, breaking down the stored triglycerides into free fatty acids and glycerol and releasing them though channels in the cell membranes. The fatty acids and glycerol are then transported around the body to the tissues that will use them during metabolism to create energy. This process of fatty acid release is a natural response of the body when the body needs to used stored energy reserves, thus laser lipolysis is not creating any unnatural reaction in the body nor does it affect or damage any surrounding structures such as skin, blood vessels and peripheral nerves. A period of exercise post treatment will ensure the complete metabolism and thus elimination from the body of the freed fatty acids.

1) Notice before Operation

Discuss with customers about the treatment thoroughly, make sure you have 100% understand customer’s requirements about the treatment; then decide whether to start the treatment or not. Explain the treatment to customer as clear as possible. Clean the treatment area, make sure there is no grease, scruffs nor cosmetics, and the pores are clear to see. Firstly, use hot towel to warm the skin, and then wipe up the skin.

2) Operation Cautions

1. The machine must be operated correctly.

2. Patients using the following medical electrical equipment can not use the machine.

Implanted cardiac pacemakers or other implanted electronic devices;

Life-sustaining artificial heart-lung machines and other equipment;

Portable ECG measurement equipment

3) Contraindications

People who has fever, infectious diseases, acute diseases

Pregnant women

Do not use at the abdomen during menstrual period

People with hemorrhagic disease, trauma, vascular rupture, skin inflammation, skin disease

Those who is anemic, erythroid, aplasia or hemorrhage

Those who is dysphemia

Patients with severe high blood pressure, tumor disease, asthma, deep vein thrombosis

Those who suffer from heart failure

People with heart disease or configured cardiac pacemaker

Medical plastic parts, or parts with metal inside

Varix, thyroid, cancer, falling sickness

People with an abnormal immune system

4) Treatment Course Setting

One treatment time is about 10-40 minutes (depending on the capacity of the human body set). Each time just can treat one part. Regarding the cellulite of waist, if you want to treat the whole waist, you may need to receive multiple treatments to achieve the ideal weight loss effect.

 

Lipolaser

4 weeks/ course

4 treatments first week

Each time 30 minutes

3 treatments second week

Each time 25 minutes

3 treatments third week

Each time 25 minutes

2 treatments the last week

Each time 20 minutes

 

5) Operation Process

1. Check the thickness of the fat.

2. Clean treatment area; Clear the hair of the treatment area.

3. Mark the size of treatment area.

4).The Lipolaser treatment, using the belt to fixed the pads on the treatment parts of body, wearing goggles and glasses.

5) Can put the laser pads on these areas: stomach, hips, thighs, calves, back, baby bulge, male breasts, and chin.


 

 

1) Cleaning of the system

 

Clean this system once a week minimally. Switch off the equipment, and wipe the surface with a soft, wet tissue, especially the window of the hand piece. Please take care that you don’t pour any liquids on to the system. After each treatment, the window of the hand piece should be cleaned.

 

2) Maintenance Instruction

 

1. Medical equipment or appliances close to the device may be resulting in operational failure due to interference,

2. The machine is a precise apparatus; do not use it at place with high temperature, humidity, dusty, smokes, and vapor.

3. If there comes a failure, please shut down the power immediately, and send it to the distributor or manufacturer for maintenance. Do not repair on your own.

4. Exclusion of liability

If fire, earthquake, war occurred.

The fault of the user, operator error;

Damage caused by using other method (not included in the use manual).

Operate without the manual's guide.


Technical Parameters

 

Wavelength

650nm

Energy output

25 x 100mW , 36 x 100mw

Voltage

AC110V-240V/50Hz-60Hz

Diode laser type

Mitsubishi ML101J27

Safety

On Board Diagnostics

Classification

Electrical Class 1, Type B applied part

Cooling requirements

Air cooling

Mode of operation

Continuous

Diodes standard

25 diodes or 36 diodes

Environmental requirements:

0°C to 40°C Non-condensing Humidity Below 75%RH

Package Size

25cm*17cm*15cm

N.W & G.W:

1.0kgs / 1.2kgs

Accessory list

Lipo laser pad * 1pc

Power line * 1pc

Elastic bands *3pcs



Send A Message
*If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.