Face Lift, Pigment Removal, Skin Rejuvenation, Skin Tightening, Wrinkle Remover, Acne Treatment
CO2 fractional laser causes a controlled and highly precise photothermal effect into the vaginal mucosa, promoting tissue contraction and tightening and returning its natural elasticity to the vaginal canal. The laser energy delivered along the vaginal wall heats the tissue without damaging it and stimulating the production of new collagen in the endopelvic fascia.
Our products have obtained various domestic and international certifications, including CE, ISO, NMPA, ROSH, TGA, etc.,demonstrating that our product quality and performance meet international standards also fully reflects the professionalism and rigor in our quality management system, as well as in various aspects such as product design, R&D, and production.
1. Theory
The wavelength of CO2 laser is 10.6μm, which can be fully absorbed by human biology tissue (all the skin are available). The sealed-off fractional CO2 laser, whose output laser-light will be transferred by articulated arm, which has better sense of direction and higher energy density.
The CO2 laser operates in the invisible infrared waveband, and an aiming beam is required to see where the treatment beam will impact tissue more recently from a visible red diode laser. When the laser beam go through the focus lens, the produced heat will gasify the target tissue.
With fractional laser resurfacing the laser beam is broken up or fractionated into many small micro beams which are separated so that when they strike the skin surface small areas of the skin between the beams are not hit by the laser and left intact. These small areas of untreated skin promote a much more rapid recovery and healing with less risk of complications. The small areas treated by the fractional micro beams, called micro treatment zones, cause sufficient laser injury to promote new collagen production and resultant facial skin rejuvenation.
Intimate Laser is a non-invasive laser pelvic floor repair technology without surgery. Using the micro-pulse stimulation effect of CO2 laser, it increases cell oxidation and nutrients, and a large number of fibroblasts synthesise and secrete into collagen fibres, elastin fibres, reticular fibres and organic matrix, so as to make the vaginal wall thickened and the vagina tightened, and to activate women's own repairing ability.
2. Application
(1) Remove acne and acne marks.
(2) Eliminate dry pattern, fishtail, etc around the eyes.
(3) anti-aging: skin firming, wrinkle removal, improve the skin condition.
(4) Treatment of pigmentary lesions such as freckles and ostrum miracles.
(5) Scar: treatment of depressed, old dispersion, convex vascular / fibrous scar.
(6) Stretch marks.
(7) Improves tissue tone and tightness in the labia externa and inside the vagina, tightens the skin and tissues, improves the tone, softness and moistness of the tissues.
6. Contraindications
(1) scar body.
(2) Severe diabetes, hypertensive patients.
(3) Treatment zone has suspicious villain.
(4) Vitiligo and psoria, systemic lupus erythematosus.
(5) Pregnancy or lactation.
(6) Light allergy.
(7) Chemical peeling and removal, grinding and other transconductors.
(8) Use dimromic acidists.
(9) Cardiopulmonary function is poor, and it is important organic lesions.
(10) Vaginal Treatment: active infections of the genitourinary tract: Candida, Chlamydia, Herpes, Gonorrhea, and other common bacteria; history of CIN, VIN malignancy; unexplained abnormal bleeding; diabetes mellitus, suboptimal glycemic control; recent vaginal trauma; pregnancy, menstruation; severe medical and surgical disorders.
7. Product Maintenance
(1) Warranty: one year from the date of purchase for the main unit and six months for the handle. We are responsible for the maintenance in our factory in GZ. After the warranty period has expired, we will charge a service fee or component fee.
(2) Medical equipment or household appliances near the equipment may have operational failures due to interference.
(3) Prohibited to use in the following environments: hot and humid environment; dusty environment; environment with much smoke or stream.
(4) If there comes a failure, shut down the power immediately, and send it to the distributors or contact manufacturer for maintenance, Do not repair by yourself without guidance.
(5) The cooling liquid is pure water, and it is necessary to clean up when the machine is transported or not used for a long time.
(6) After treatment, turn off the power, ensure that the power line is unplugged.
(7) Exclusion of liability:
failure caused by unauthorized disassembly and modification;
failure caused by accidental falling;
failure caused by lack of reasonable maintenance;
failure caused by incorrect usage.
Parameters
Working mode | single pulse, continuous pulse, repeat pulse, super pulse |
Output power | 1-60W (adjustable) |
Input power | 450VA |
Laser type | Sealed-off CO2 laser |
Laser wavelength | 10.6μm |
Divergence angle | 4mrad |
Focused spot diameter | ≤0.4mm |
Tool bit focus | F=100mm (optional) |
Pulse width | 0.1ms-10ms |
Aiming beam | Red diode laser (650nm, 2mW) |
Transmission system | Spring-balanced 7 joint arms |
Cooling system | Inside-circle coolant |
Display screen | 12.1inch touch screen |
Working environment temperature | 5-40℃ |
Air pressure / Humidity | 86Kpa-106 Kpa /<80% |
Preheating-time | >5min |
Electromagnet | No electromagnet interrupt |
other working environment | No obvious shaking or airflow |
N. W./G. W. | 39kgs/56kgs |
Size | 116cm×58cm×47cm; 75cm×31cm×14cm (Laser Arm) |
Our professional team can provide customers with fast, accurate, and thoughtful pre-sales consultations and after-sales services, ensuring a worry-free purchasing and usage experience for customers.